{"dppId":"EU-DPP-2026-00000002","gtin":"09521234500001","serial":"BAT-2026-06-A-0002","vc":{"@context":["https://www.w3.org/ns/credentials/v2","https://dpp.primecredence.io/contexts/battery-dpp/v1.jsonld"],"id":"https://dpp.primecredence.io/dpp/BAT-2026-06-A-0002","type":["VerifiableCredential","BatteryDigitalProductPassport"],"issuer":"did:web:consumer.dpp.demo.primecredence.com","issuanceDate":"2026-06-04T08:00:00Z","credentialSubject":{"id":"urn:gtin:09521234500001:serial:BAT-2026-06-A-0002","gtin":"09521234500001","serialNo":"BAT-2026-06-A-0002","gs1:gtin":"09521234500001","gs1:serialNumber":"BAT-2026-06-A-0002","gs1:sgtin":"urn:epc:id:sgtin:0952123.4500001.BAT-2026-06-A-0002","gs1:digitalLinkURI":"https://consumer.dpp.demo.primecredence.com/01/09521234500001/21/BAT-2026-06-A-0002","gs1:batchLotNumber":"LOT-2026-05-A","espr:registrationNumber":"EU-DPP-2026-00000003","_richViewURI":"https://consumer.dpp.demo.primecredence.com/dpp-rich/BAT-2026-06-A-0002","_narrative":"NMC chemistry — Class B carbon, full cobalt due-diligence trail (DRC sourcing → OECD-aligned).","carbonPerformanceClass":"B","carbonClassProof":{"type":"AnonCredsDerivedPredicateProof","predicate":{"attribute":"carbonFootprint","operator":"<","threshold":45},"declaredClass":"B","sourceCredentialIdHash":"3f16dfd40395395075da44c1b721f2590602b9ed9dfe979b339734c1ab4780bd","sdkVerificationResult":{"verified":true,"predicateSatisfied":true,"method":"anoncreds-cl-derived-predicate","verifierNote":"hidden carbon value < 45 kg CO2e/kWh → derives Class B per CARBON_CLASS_THRESHOLDS"}},"regulatorTier":{"carbonFootprintNumeric":42.1,"carbonStudyReference":"EU-LCA-BATTERY-2025","verificationBodyId":"did:web:bureau-veritas.example","testReportId":"dcc-BAT-2026-06-A-0002","facilityId":"FAC-TOL-01","energySourceMix":{"renewable_percent":38,"grid_carbon_intensity_gCO2kWh":218},"csdddStatus":"COMPLIANT"},"publicTier":{"batteryCategory":"INDUSTRIAL","batteryModel":"Interstate MTP-78 AGM (NMC stationary)","gs1:batteryModelId":"CLARIOS-MTP-78-NMC-2026","batteryChemistry":"NMC","manufacturer":"Clarios LLC","manufacturingCountry":"US","dateOfManufacture":"2026-05-19","carbonPerformanceClass":"B","totalRecycledContentPct":9.7,"espr:takeBackScheme":true,"espr:collectionPointURI":"https://consumer.dpp.demo.primecredence.com/collection-points","espr:safeHandlingInstructions":"https://consumer.dpp.demo.primecredence.com/safety/nmc-handling","espr:ceMarkingStatus":{"marked":true,"date":"2026-05-19"},"espr:regulatoryComplianceStatus":"COMPLIANT","espr:reusable":true,"carbonClassProof":{"type":"AnonCredsDerivedPredicateProof","predicate":{"attribute":"carbonFootprint","operator":"<","threshold":45},"declaredClass":"B","sourceCredentialIdHash":"3f16dfd40395395075da44c1b721f2590602b9ed9dfe979b339734c1ab4780bd","sdkVerificationResult":{"verified":true,"predicateSatisfied":true,"method":"anoncreds-cl-derived-predicate","verifierNote":"hidden carbon value < 45 kg CO2e/kWh → derives Class B per CARBON_CLASS_THRESHOLDS"}}},"supplierContribution":{"_contributedBy":"did:web:clarios.dpp.demo.primecredence.com","_actorLabel":"Clarios LLC — Cell Supplier","_actorRole":"Component Supplier (Stage 1)","_credentialType":"DigitalTwinOfEquipment","_credentialId":"dte-BAT-2026-06-A-0002","_issuedAt":"2026-05-15T10:00:00Z","gs1:partyGLN":"5400000000002","gs1:locationGLN":"5400000000001","espr:facilityId":"FAC-TOL-01","schema:material":[{"name":"Lithium Nickel Manganese Cobalt Oxide","weightKg":16.8,"weightPercent":46.7,"casNumber":"182442-95-1","criticalRawMaterial":true,"recycledContentPercent":9},{"name":"Graphite","weightKg":9.1,"weightPercent":25.3,"casNumber":"7782-42-5","criticalRawMaterial":true,"recycledContentPercent":0},{"name":"Cobalt (in cathode)","weightKg":1.8,"weightPercent":5,"casNumber":"7440-48-4","criticalRawMaterial":true,"recycledContentPercent":12,"sourcingCountry":"CD","ddPolicy":"OECD"},{"name":"Nickel (in cathode)","weightKg":2.6,"weightPercent":7.2,"casNumber":"7440-02-0","criticalRawMaterial":true,"recycledContentPercent":9,"sourcingCountry":"ID"},{"name":"Aluminium","weightKg":4.2,"weightPercent":11.7,"casNumber":"7429-90-5","criticalRawMaterial":false,"recycledContentPercent":42},{"name":"Copper","weightKg":1.5,"weightPercent":4.1,"casNumber":"7440-50-8","criticalRawMaterial":false,"recycledContentPercent":35}],"espr:criticalRawMaterial":true,"espr:recycledContentPercent":{"lithium":8,"cobalt":12,"nickel":9,"lead":0},"espr:hazardousSubstances":[{"name":"Lithium hexafluorophosphate (electrolyte)","casNumber":"21324-40-3","concentrationPercent":1.8,"reach_svhc":false}],"espr:reachCompliance":"COMPLIANT","espr:lithiumOriginCountry":"AU","espr:cobaltOriginCountry":"CD","espr:nickelOriginCountry":"ID","espr:tier1Suppliers":[{"did":"did:web:clarios.dpp.demo.primecredence.com","gln":"5400000000002","role":"CELL_MANUFACTURER"}],"espr:supplyChainTiers":[{"tier":1,"role":"Cell Manufacturer","did":"did:web:clarios.dpp.demo.primecredence.com","gln":"5400000000002","country":"US","facility":"Clarios Toledo Cell Plant"},{"tier":2,"role":"Lithium Refiner","did":"did:web:ganfeng.example","gln":"5400000000010","country":"CN","facility":"Ganfeng Lithium Refinery"},{"tier":3,"role":"Lithium Mining","did":"did:web:talison-lithium.example","gln":"5400000000011","country":"AU","facility":"Greenbushes Mine (AU)"},{"tier":2,"role":"Cobalt Refiner","did":"did:web:huayou-cobalt.example","gln":"5400000000020","country":"CN","facility":"Huayou Cobalt Refinery"},{"tier":3,"role":"Cobalt Mining","did":"did:web:cmoc-tenke.example","gln":"5400000000021","country":"CD","facility":"Tenke Fungurume Mine (DRC, OECD-aligned)"},{"tier":2,"role":"Nickel Refiner","did":"did:web:vale-indo.example","gln":"5400000000030","country":"ID","facility":"Vale Sorowako Refinery"}],"espr:dueDiligenceStatus":"COMPLIANT","espr:dueDiligenceReport":"https://clarios.dpp.demo.primecredence.com/docs/due-diligence-2026.pdf","espr:supplyChainRiskScore":34,"espr:ratedCapacityWh":5400,"espr:ratedPowerKw":11.2,"espr:ratedCycleLife":2400,"espr:expectedLifetimeYears":12,"espr:bmsVersion":"CLARIOS-BMS-v3.2.1"},"certifierContribution":{"_contributedBy":"did:web:bureau-veritas.dpp.demo.primecredence.com","_actorLabel":"Bureau Veritas (DE-CAB-001) — Notified Body","_actorRole":"Certifier / Notified Body (Stage 2)","_credentialType":"DigitalConformityCertificate","_credentialId":"dcc-BAT-2026-06-A-0002","_issuedAt":"2026-05-22T14:00:00Z","espr:carbonFootprintLifecycle":42.1,"espr:carbonCalcScope":"CRADLE_TO_GATE","espr:carbonMethodology":"EU-LCA-BATTERY-2025","espr:manufacturingEnergyMix":{"renewable_percent":38,"grid_carbon_intensity_gCO2kWh":218},"espr:carbonVerificationStatus":"THIRD_PARTY_VERIFIED","espr:carbonVerifier":"Bureau Veritas (DE-CAB-001)","espr:carbonPerformanceClass":"B","espr:carbonDeclaredAt":"2026-05-20T00:00:00Z","espr:stateOfHealth":99.5,"espr:stateOfCharge":80,"espr:degradationProfile":{"cycles_to_80pct":1800,"calendar_years_to_80pct":9,"temp_sensitivity":"medium"},"espr:remainingUsefulLifeYears":11.6,"espr:performanceAtRatedTemp":{"cold_temp_c":-10,"cold_capacity_pct":76,"hot_temp_c":45,"hot_capacity_pct":92},"espr:recyclingEfficiencyPercent":74,"espr:materialRecoveryRates":{"lithium_pct":78,"cobalt_pct":92,"nickel_pct":88,"lead_pct":0,"copper_pct":78},"espr:wasteClassificationCode":"16 06 04","espr:declarationOfConformity":"https://clarios.dpp.demo.primecredence.com/docs/doc-2026-batch-a-0002.pdf","espr:conformityAssessmentType":"THIRD_PARTY","espr:assessorIdentity":"did:web:bureau-veritas.dpp.demo.primecredence.com","espr:auditReferences":["https://clarios.dpp.demo.primecredence.com/docs/audit-2026-q2.pdf"]},"anchorContribution":{"_contributedBy":"did:web:consumer.dpp.demo.primecredence.com","_actorLabel":"Clarios DPP Anchor (Brand Owner)","_actorRole":"Brand Owner / Assembler (Stage 3)","_credentialType":"BatteryDigitalProductPassport","_credentialId":"dpp-BAT-2026-06-A-0002","_issuedAt":"2026-06-04T08:00:00Z","gs1:partyGLN_EOID":"5400000000001","espr:eoid":"5400000000001","espr:fids":["5400000000001"],"schema:name":"Interstate MTP-78 AGM (NMC stationary)","schema:description":"Clarios NMC battery, model Interstate MTP-78 AGM (NMC stationary), manufactured at FAC-TOL-01 (Toledo, OH). EU Battery Regulation 2023/1542 compliant.","espr:subDppURIs":["https://clarios.dpp.demo.primecredence.com/sub-dpp/dte-BAT-2026-06-A-0002","https://bureau-veritas.demo.primecredence.com/sub-dpp/dcc-BAT-2026-06-A-0002"],"espr:endOfLifeInstructions":"https://consumer.dpp.demo.primecredence.com/eol/nmc","espr:disassemblyInstructions":"https://consumer.dpp.demo.primecredence.com/disassembly/nmc","espr:repurposingSuitability":"STATIONARY_STORAGE","espr:accessTiers":{"consumer":"public","regulator":"OID4VP_RVC","second_life_operator":"OAUTH_PKCE","recycler":"OAUTH_PKCE"},"espr:marketSurveillanceAccess":true,"espr:integrityHash":"<computed-at-publish>","espr:registryEndpoint":"https://acme-dpp-registry.dpp.demo.primecredence.com/","espr:publishedAt":"2026-06-04T08:00:00Z","espr:delegatedActVersion":"2025-DA-BATTERY-v1"}},"proof":{"type":"DataIntegrityProof","cryptosuite":"eddsa-jcs-2022","created":"2026-06-05T13:00:00Z","verificationMethod":"did:web:consumer.dpp.demo.primecredence.com#key-1","proofPurpose":"assertionMethod","proofValue":"z48NGusURrUWYVb3ASDJ32kE5AnwreprvUu8ai1BtYFkvVdnWoKKyCkbrNNzJoLMpow7aNnn32be3G7nVz4F2swt9"}},"publishedAt":"2026-06-05T09:34:32.236Z","revoked":false}